Lead-acid battery specification sheet


Contact online >>

HOME / Lead-acid battery specification sheet

SPECIFICATIONS ES7-12 12Volt 7.2Ah ES7-12

SPECIFICATIONS ES7-12 12Volt 7.2Ah Maintenance-Free Rechargeable Sealed Lead-Acid Battery Nominal Voltage (V) ES7-12 ES7-12 12V

CSB GP121000 Lead Acid 100Ah Battery Datasheet

Valve Regulated Lead Acid Battery Maintenance-Free Sealed Lead Acid Battery.

SPECIFICATIONS ES7-12 12Volt 7

SPECIFICATIONS Maintenance-Free Rechargeable Sealed Lead-Acid Battery DIMENSIONS ES7-12 ES7-12 12Volt 7.2Ah Specifications Nominal Voltage(V) 12V Nominal Capacity 20 hour rate (0.36A to 10.50V) 7.2Ah 10 hour rate (0.684A10.50V) to 10.50V) 6.84Ah 5 hour rate (1.224A10.20V) to 10.20V) 6.12Ah 1 C (7.2A to 9.60V) 4.08Ah

TECHNICAL DATA SHEET FOR EP 200-12 (12V 200AH)

TECHNICAL DATA SHEET FOR EP 200-12 (12V 200AH) VRLA BATTERY CONSTRUCTION: -tin calcium alloy. Separator - low resistance micro porous glass fiber. The electrolyte is absorbed within this material, preventing acid

(12V 100Ah)

Rechargeable Sealed Lead Acid Battery (12V 100Ah) BG-121000NB These rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus

(12V 18Ah)

Technical Specification Sheet Application · Alarm System · Cable Television · Communication Equipment · Control Equipment · Security System · Medical Equipment Rechargeable Sealed Lead Acid Battery (High Rate Series) BGH-12180NB (12V 18Ah) Charge characteristic Discharge characteristic (25°C)

Sealed Lead Acid Batteries Technical Manual Version 2

1. Construction of Sealed lead acid batteries 2. Reactions of Sealed lead acid batteries 3. Sealed lead acid batteries characteristics 3.1 Battery capacity 3.2 Battery voltage 3.3 Battery self discharge 3.4 Battery internal resistance 3.5 Battery life 4. Operation of sealed lead acid batteries 4.1 Preparation prior to operation

CSB GP12200 Lead Acid 20Ah Battery Datasheet

Specification Nominal Voltage 12V (6 cells per unit) 20 Ah @20hr-rate to 1.75V per cell @25℃ (77℉) Weight Approx. 6. GP 12200 12V 20AH Valve Regulated Lead Acid Battery Design for Standby Power Applications Nominal Operating Temperature : 25℃(77℉) Title: CSB GP12200 Lead Acid 20Ah Battery Datasheet Author: Server Room Environments

TECHNICAL SPECIFICATION

[iii] IS-6071-1986 - Specification for synthetic separators for lead acid batteries. [iv] IS:1069-1993 Specification for quality tolerances water for storage batteries. [v] IS:1146-1981 - Specification for rubber and plastic containers for lead acid storage batteries. [vi] IS:8320-2000 - General requirements and methods of tests for lead-acid

(12V 1.2Ah/20hr)

Rechargeable Sealed Lead Acid Battery (12V 1.2Ah/20hr) BG-1212F1 These rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus

(12V 12Ah)

Rechargeable Sealed Lead Acid Battery (12V 12Ah) BGH-12120F2 Technical Specification Sheet Application · Alarm System · Cable Television · Communication Equipment · Control Equipment Lead Acid batteries are designed with AGM

Duracell Ultra SLA Product Sheet

SEALED LEAD ACID Duracell® Ultra Deep Cycle AGM Batteries are designed to achieve maximum cycles throughout the life of the battery. PRODUCT SHEET batteriesplus | 1-800-677-8278 Questions About Products? PRODUCT LINE Vendor Product # Voltage Capacity (20 Hr Test) Terminal Type Length (in) Width (in) Height+ (in)

Lead carbon battery

It takes time to recharge a lead acid battery Ideally, a lead acid battery should be charged a ra te not exceeding 0,2C, and the bulk charge phase should be fo llowed by eight hours of Specification s Article number V Ah C5 (10,8V) Ah C10 (10,8V) Ah C20 (10,8V) l x w x h mm Weight kg CCA @0°F RES CAP @80°F Terminals

LEAD-ACID BATTERY SPECIFICATIONS

lead-acid battery specifications 254756 DVX24HL-BS 8.0 3.5 6.4 - + M 360 12 23 254757 DVX20HL-BS 6.9 3.5 6.1 - + M 320 12 20

Exide Technologies Lead Acid Batteries Data Sheets

Find Exide Technologies Lead Acid Batteries Data Sheets on GlobalSpec. Home. Products & Services. Engineering News. Standards. Webinars. Lead acid batteries are made up of plates, lead, and lead oxide with a 35% sulfuric acid and 65% water electrolyte solution. lead-acid (VRLA) battery brands. Design life in years: 20 @ 25°C Nominal

Downloadable Technical Sheets – Osaka Batteries

Battery Test; Contact Us; Home / Downloadable Technical Sheets. Downloadable Technical Sheets. Osaka Tubular Technical Data Sheet. Osaka MCB VRLA Technical Data Sheet. About Osaka. An ISO 9001, 14001 & 45001, RoyalCert certified company, we have been producing various types of automotive and inverter batteries, under the brand name of

Hawker® Battery Specifications + Data Sheets

For example, the Hawker ® ARMASAFE ™ Plus 6TAGM battery is a lead-acid battery (in fact, the battery''s plates are 99.99% pure lead), and each of its six nominal 2-volt cells has an independent pressure-relief valve to regulate any

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION FOR LEAD ACID BATTERIES (30 V, 100 AH) type Lead Acid Cell Battery 1 no. 02 Cell Testing Voltmeter (Range: 3-0-3 volts having scale conforming to IS )/ Digital Multimeter 1 no. 03 Mercury Glass Thermometer Range:

Technical Specification Sheet BC-630

Technical Specification Sheet These rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus avoiding excessive pressure build-up.

(12V 9Ah)

Technical Specification Sheet Application · Alarm System · Cable Television · Communication Equipment · Control Equipment · Security System · Medical Equipment Rechargeable Sealed Lead Acid Battery (High Rate Series) BGH-1290F2 (12V 9Ah) Charge characteristic Discharge characteristic (25°C)

Sealed Lead-Acid Batteries

Proper selection of the battery for a specific application can be made from this graph if the required time and current are known. For example, to determine the proper capacity of a

CSB GPL121000 Lead Acid 100Ah Battery Datasheet

Valve Regulated Lead Acid Battery Design for Standby Power Applications Nominal Operating Temperature : 25℃(77℉) Discharge : -15℃ ~ 50℃ (5℉~122℉) Charge: -15℃ ~ 40℃ (5℉~104℉) Specification Nominal Voltage 12V (6 cells per unit) Weight Approx. 33.50 Kg (73.83 lbs) Maximum Discharge Current 800A (5sec) Internal Resistance

Sealed Lead-Acid Battery Deep Cycle 727-0414(12V7.2Ah)

Specification Sealed Lead-Acid Battery Deep Cycle 727-0414(12V7.2Ah) Constant Current Discharge Characteristics : A (25 0 C ) Constant Power Discharge Characteristics : W (25 0 C ) D im en si o n s Unit: mm Dimension:151(L) 65(W) 93.5(H) Terminal T1 Applications Electric tools Mobility Lawn mowers Golf trolleys and golf cart

Technology: Lead-Acid Battery

Figure 1: Schematic view of a lead-acid battery with chemical reactions for charging and discharging Suitable fields of application Figure 3: Armoured plate battery, grid plate battery, large surface battery (f.l.t.r.) TECHNICAL SPECIFICATIONS Specific energy storage density kWh/m³ kWh/t 60-90 35 Specific power density kW/m³ kW/t

(12V 100Ah)

Rechargeable Sealed Lead Acid Battery Technical Specification Sheet de systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus mmobilized. Should the battery be

(12V 7.0Ah/20hr)

Rechargeable Sealed Lead Acid Battery (12V 7.0Ah/20hr) BG-1270F1 & F2 These rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the gases to escape thus

FLA Deep Cycle Battery D /S SHEETS

DATA SHEET Deep Cycle 6 -Volt Application: Wherever Deep Cycle 6-volt batteries are needed. Dimensions: 10-1/4 (260)L x 7-1/8 (181)W x 11-1/4 (286)H Type: Flooded Lead Acid (FLA) non-sealed. Case material: Polypropylene / Heat Sealed US 1800 XC2, US 2000 XC2, US 2200 XC2 - SPECIFICATIONS

Download Center

Download technical specification sheets, MSDS, certifications, approvals and user manuals for all Power Sonic battery products - lead acid and lithium

SPECIFICATIONS ES7-12 12Volt 7

SPECIFICATIONS ES7-12 12Volt 7.2Ah Maintenance-Free Rechargeable Sealed Lead-Acid Battery Nominal Voltage (V) 12V

(12V 7.5Ah)

Technical Specification Sheet Application · Alarm System · Cable Television · Communication Equipment · Control Equipment · Security System · Medical Equipment Rechargeable Sealed Lead Acid Battery (High Rate Series) BGH-1275F2 (12V 7.5Ah) Charge characteristic Discharge characteristic (25°C)

TECHNICAL DATA SHEET FOR EP 150-12

TECHNICAL DATA SHEET FOR EP 150-12 (12V 150AH) VRLA BATTERY CONSTRUCTION: Positive and negative plates in lead -tin calcium alloy. Separator low resistance micro porous

Lead carbon battery

Ideally, a lead acid battery should be charged a rate not exceeding 0,2C, and the bulk charge phase should be followed by eight hours of absorption charge. Increasing charge current and

(PDF) LEAD-ACİD BATTERY

The lead-acid battery is the oldest and most widely used rechargeable electrochemical device in automobile, uninterrupted power supply (UPS), and backup systems for telecom and many other

Sealed Lead-Acid Battery UPG No. 45978 UB121000

UPG No. 45978 Maintenance-Free UB121000 488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi

NP7-12 Data Sheet

Reliability is your Security Yuasa NP, NPC and NPH Batteries. Utilising the latest advance design Oxygen Recombination Technology, Yuasa have applied their 80 years experience in the lead

Download Center

Download technical specification sheets, MSDS, certifications, approvals and user manuals for all Power Sonic battery products - lead acid and lithium. VIEW THE EVESCO WEBSITE . GOLF CART lead acid battery. Download. IATA - SLA US. Download. IATA Air Certificate (Batts) Download. IATA Air Certificate (Elect Equip) Download. IMDG Sea Cert.

6 FAQs about [Lead-acid battery specification sheet]

What are the characteristics of lead acid batteries?

LEAD ACID BATTERIES : 5.1 The batteries shall be made of closed type lead acid cells of very low internal resistance having high cycling capability ,moderate size, high service life minimum 20 years, excellent performance for both low & high rates of discharge, rigid cell plates design type manufactured to conform to

Why should you choose a sealed lead-acid battery?

The high energy density results in superior power/volume and power/weight ratios. No special handling precautions or shipping containers – surface or air – are required due to leak-proof construction. The high watt-hour per dollar value is made possible by the materials used in a sealed lead-acid battery: they are readily available and low in cost.

How long does a lead carbon battery last?

The tests consist of a daily discharge to 10,8V with I = 0,2C20, followed by approximately two hours rest in discharged condition, and then a recharge with I = 0,2C20. (Several manufacturers of lead carbon batteries claim a cycle life of up to two thousand 90% DoD cycles. We have not yet been able to confirm these claims)

Why should you choose a lead carbon battery?

Lower charge voltage and therefore higher efficiency and less corrosion of the positive plate. And the overall result is improved cycle life. Tests have shown that our lead carbon batteries do withstand at least five hundred 100% DoD cycles.

What is a heavy duty lead calcium alloy grid?

The heavy duty lead calcium alloy grids provide an extra margin of performance and life in both cyclic and float applications and give unparalleled recovery from deep discharge. Depending upon the average depth of discharge, over a thousand discharge/charge cycles can be expected.

Is a lead-acid battery overcharging or undercharging?

Continuous over- or undercharging is the single worst enemy of a lead-acid battery. Caution should be exercised to insure that the charger is disconnected after cycle charging, or that the float voltage is set correctly.

Expert Industry Insights

Timely Market Updates

Customized Solutions

Global Network Access

Battery Power

Contact Us

We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.