Some single-phase require a "run capacitor" to energize the second-phase winding (auxiliary coil) to create a rotating magnetic field while the motor is running. Run capacitors are designed for continuous duty while the motor is powered, which is why electrolytic capacitors are avoided, and low-loss are used. Run capacitors are mostly polypropylene (historically: metallised paper capacitors) and are energize. A run capacitor is used to continuously adjust current or phase shift to a motor's windings in an effort to optimise the motor's torque and efficiency performance. [pdf]
In this topic, you study Capacitor Run Motor – Theory, Construction, Diagram, Working & Torque Speed Characteristic. Capacitor Run motors are commonly called as fan motors. In Capacitor Run Motor, the auxiliary winding (A) along with the capacitor (C) is in the circuit for both, starting and running (Fig. 1).
The capacitor C R is connected permanently in the circuit and thus it is known as RUN Capacitor. The run capacitor is long time rated and is made of oil-filled paper. The figure below shows the Phasor Diagram of the Capacitor Start Capacitor Run Motor.
The capacitor run induction motor is same as the capacitor start induction motor, where the capacitor is connected in series with the starting winding throughout its operation. Under this condition, the motor runs as if it is a two-phase motor but with unbalanced currents.
A motor capacitor is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run capacitor).
The working principle of the capacitor start capacitor run motor relies on creating a rotating magnetic field using phase correction provided by the capacitors. At startup, the starting capacitor (Cs) connected in series with the auxiliary winding generates a leading current which is 90° ahead of the main winding current.
This hesitation can cause the motor to become noisy, increase energy consumption, cause performance to drop and the motor to overheat. A dual run capacitor supports two electric motors, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case.

A motor capacitor is an electrical that alters the current to one or more of a to create a rotating magnetic field. There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run capacitor). Motor capacitors are used with that are in turn use. A dual run capacitor supports two electric motors, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. [pdf]
This hesitation can cause the motor to become noisy, increase energy consumption, cause performance to drop and the motor to overheat. A dual run capacitor supports two electric motors, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case.
Three phase electric motors do not use start/run capacitors. Electric motors that use start/run capacitors may be PSC (permanent split capacitor) and CSR / CSCR (capacitor start, capacitor run) designs.
A dual run capacitor will always have [at least] three wiring terminals - as you can see on both examples above, while a simple single-use "run" capacitor will have only two terminals providing a single MFD capacity. In contrast with a dual run capacitor that serves two motors, single-run capacitor serves just one motor.
The term "dual capacitor" can be confusing because there are two kinds of "dual capacitors": Dual Start/Run Capacitors - three- lead capacitors to combine "start" function and "run" function in a single device. So a dual capacitor for a fan motor will have three leads,
5 MFD - smaller number (5uf) is the smaller capacitor used to run the compressor/condenser unit's cooling fan motor. The particular starting capacitor to be purchased is matched to the horsepower range and voltage of the compressor or motor being repaired. Many motor starter capacitors to support a pretty wide range of motors.
The dual ratings in a single can provide two capacitors - one may be used as a fan capacitor and the other as a compressor or motor run capacitor. Three terminals allow one terminal to act as a common while the other two are connected to the individual capacitors. Trust the wiring diagram. Here is a typical SF type capacitor specification sheet:

Unlike resistors, capacitors use a wide variety of codes to describe their characteristics. Physically small capacitors are especially difficult to read, due to the limited space available for printing. The information in this article should help you read almost all modern consumer capacitors. Don't be surprised if your information is. Inspect the surface of the capacitor and look for any numbers printed on it. The numbers are usually expressed as a three-digit value. The numeric value directly represents the capacitance. [pdf]
A: Capacitor code values are used to represent the capacitance value of a capacitor component. Capacitors are electronic components that store and release electrical energy. The code values help in identifying the capacitance value of a capacitor without having to write the full value in Farads. Q: How are capacitor code values expressed?
Some small capacitors are marked with codes like 1n0. The digits are the values before and after the decimal point and the the character tells you the dimension; so the example given is 1.0 nF (nano-Farad). Look for a letter code. Some capacitors are defined by a three number code followed by a letter.
The various parameters of the capacitors such as their voltage and tolerance along with their values is represented by different types of markings and codes. Some of these markings and codes include capacitor polarity marking; capacity colour code; and ceramic capacitor code respectively.
To read a large capacitor, first find the capacitance value, which will be a number or a number range most commonly followed by µF, M, or FD. Then look for a tolerance value, typically listed as a percentage. Next, check the voltage rating, which is usually listed as a number followed by the letters V, VDC, VDCW, or WV.
Some capacitors use letter codes to indicate specific characteristics, such as tolerance, voltage rating, or the type of dielectric material used. These letter codes are often combined with numbers to give full specifications. Voltage Rating: Some capacitors mark the voltage rating using a letter code like V or WV (working voltage).
Numerical Markings One of the most common formats for capacitor markings is the numerical code. This is typically a series of three or four digits, which represent the capacitance value and sometimes the tolerance. Three-digit code: The first two digits represent the significant figures, and the third digit indicates the number of zeros to add.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.