In any electric motor application, the target equipment performance dictates the required motor power. The rated power of the motor is calculated from the combination of speed, torque, and duty cycle of the application that in turn establishes the critical voltage, current, and capacity requirements of the battery.. . One motor parameter that affects the performance of battery-powered applications is efficiency. Maximizing motor efficiency helps minimize required power capacity — in turn. . One essential criterion in battery selection is ensuring the battery will satisfy the motor’s voltage and current requirements when fully charged as well as continue to meet those requirements. [pdf]
Battery-powered motor applications need careful design work to match motor performance and power-consumption profiles to the battery type. Optimal motor and battery pairing relies on the selection of an efficient motor as well as a battery with the appropriate capacity, cost, size, maintainability, and discharge duration and curve.
One key motor performance parameter to consider in a battery-powered application is efficiency. Maximizing motor efficiency helps minimize the required power capacity and hence the size and cost of the battery solution. For this reason, brushless DC (BLDC) motors are preferred over brushed DC motors but are typically higher in price.
Generally, for a higher-power motor, a higher voltage is preferable. The selection of battery parameters is based on the range required for the vehicle and the capacity to provide peak discharge current and the duration for the peak current. Battery capacity (Ah or KWh) = (Mileage Requirement / Avg speed) x Avg current or power consumption.
Matching your motor voltage and your battery voltage cannot be understated if you want your setup to even work, let alone cause serious damage. If your motor is rated at 36v, get a 36v battery and so on. Getting a 72v battery and a 48v motor will likely fry your electronics located in the motors controller.
If your motor is rated at 36v, get a 36v battery and so on. Getting a 72v battery and a 48v motor will likely fry your electronics located in the motors controller. Using too low of a voltage will not give enough voltage to even register in the controller and you will not be able to power it up.
Optimal motor and battery pairing relies on the selection of an efficient motor as well as a battery with the appropriate capacity, cost, size, maintainability, and discharge duration and curve. Battery-powered AGVs for automated warehousing require brushless dc motors engineered for top efficiency.

As a global leader in battery safety testing, we help battery-operated product manufacturers gain fast, unrestricted access to the global market. . Battery-operated products have become essential tools for business and leisure. The safety, efficiency and reliability of the batteries that power battery-operated products play a key role in. This mark signifies that the imprinted battery or product has been tested by and has met the strict requirements of Underwriters Laboratories and its nationally recognized Standards for Safety. [pdf]
Underwriters Laboratories (UL) is a global safety certification organization that tests and certifies batteries for safety and performance. Essential UL standards include: UL 1642: Tests lithium cells for safety. UL 2054: Covers battery packs for portable applications. UL 1973: Pertains to stationary batteries used in energy storage systems.
UL is an independent product safety certification organization that, in conjunction with other organizations and industry experts, publishes consensus-based safety standards. For lithium batteries, key standards are: UL 1642: This standard is used for testing lithium cells. Battery pack level tests are covered by UL 2054.
UL Solutions' battery cell certification services can test to all applicable industry standards to help ensure the performance, reliability and safety of battery cells used in an ever-growing number of products.
The battery pack certifications listed here are near universal standard industry practice for leading companies in the electronic industry. Product safety is important to all product stakeholders and passing safety certifications are an independent means of assuring products are safe.
Certification can be verified through online UL directories. Battery packages and other products bearing UL certification are subject to UL’s follow-up program to ensure that the products continue to be manufactured in adherence to its safety requirements.
A UL Listed lithium-ion battery pack, such as a complete battery pack that has adhered to UL standard requirements and undergone a rigorous testing process, is an example of a UL Listed product. UL Recognized marks, on the other hand, apply to components that are intended to be installed in another device, system or end product and not a final product.

Manufacturers specify the capacity of a battery at a specified discharge rate. For example, a battery might be rated at 100 when discharged at a rate that will fully discharge the battery in 20 hours (at 5 amperes for this example). If discharged at a faster rate the delivered capacity is less. Peukert's law describes a power relationship between the discharge current (normalized to some base rated current) and delivered capacity (normalized to the rated capacity) over some s. [pdf]
Keep the discharge power unchanged, because the voltage of the battery continues to drop during the discharge process, so the current in the constant power discharge continues to rise. Due to the constant power discharge, the time coordinate axis is easily converted into the energy (the product of power and time) coordinate axis.
Constant voltage discharge is the battery discharge operation in which the battery voltage output is held constant and where the power and current freely adjust. (‘ CV discharging ’) 3.2.4. Battery charge voltage vBat,C (t) and battery discharge voltage vBat,D (t)
Maximum 30-sec Discharge Pulse Current –The maximum current at which the battery can be discharged for pulses of up to 30 seconds. This limit is usually defined by the battery manufacturer in order to prevent excessive discharge rates that would damage the battery or reduce its capacity.
Constant current discharge is the discharge of the same discharge current, but the battery voltage continues to drop, so the power continues to drop. Figure 5 is the voltage and current curve of the constant current discharge of lithium-ion batteries.
Maximum Continuous Discharge Current – The maximum current at which the battery can be discharged continuously. This limit is usually defined by the battery manufacturer in order to prevent excessive discharge rates that would damage the battery or reduce its capacity.
The discharge rate provides you with the starting point for determining the capacity of a battery necessary to run various electrical devices. The product It is the charge Q, in coulombs, given off by the battery. Engineers typically prefer to use amp-hours to measure the discharge rate using time t in hours and current I in amps.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.