Unlike resistors, capacitors use a wide variety of codes to describe their characteristics. Physically small capacitors are especially difficult to read, due to the limited space available for printing. The information in this article should help you read almost all modern consumer capacitors. Don't be surprised if your information is. Capacitor markings are used for identifying their values and proper usage in electronic circuits. Here's a detailed breakdown of the key aspects to consider: [pdf]
Thus, for such concise markings many different types of schemes or solutions are adopted. The value of the capacitor is indicated in “Picofarads”. Some of the marking figures which can be observed are 10n which denotes that the capacitor is of 10nF. In a similar way, 0.51nF is indicated by the marking n51.
While any engineer knows that the color markings on a resistor signify the resistance, some may not realize that capacitors also have their own set of markings, which vary depending on the size of the device. This article will explore just what these markings mean on a number of different components. Important Capacitor Characteristics
The various parameters of the capacitors such as their voltage and tolerance along with their values is represented by different types of markings and codes. Some of these markings and codes include capacitor polarity marking; capacity colour code; and ceramic capacitor code respectively.
Numerical Markings One of the most common formats for capacitor markings is the numerical code. This is typically a series of three or four digits, which represent the capacitance value and sometimes the tolerance. Three-digit code: The first two digits represent the significant figures, and the third digit indicates the number of zeros to add.
SMD capacitors use compact markings to indicate their value and polarity. Look for small dots, lines, or other symbols on the capacitor body. SMD capacitors may also have a negative marking or a square pad on the PCB to indicate polarity. Use a magnifying tool to clearly read the markings on small SMD components.
The capacitors which are small in size does not provide space required for clear markings and only few figures can be accommodated in the given space in order to mark it and provide a code for their various parameters. Thus, abbreviated markings are used in such cases wherein three characters are used to mark the code of the capacitor.

The goal of passive components’ failure analysis (FA) is to determine the root cause for an electrical failure. The findings can be used by the manufacturers to improve upon the design, materials, and processes used to create their components. This leads to better quality and higher reliability components. The FA. . Javaid Qazi, Sr. Director, Technology Also, an Adjunct Faculty at the School of Materials Science and Engineering, Clemson University, Clemson, SC Masashi Ikeda, Sr.. . Authors would like to acknowledge KEMET colleagues for their help in preparing and reviewing this chapter, especially A. Parker, B. Reeves, D. Hepp, P. Bryson, M. Fulton, Z. Dou, V. Andoralov, D. Adam, M.. [pdf]
This failure can cause the enclosure to explode, smoke, ignite, harm other electrical components, or leak liquid or gas from inside the capacitor. Degradation failures may include increased leakage current, increased ESR, and decreased capacitance, although the definition of parameters and their limits vary among manufacturers *02, 03.
Electromigration is one of failure mechanisms of semiconductor, but the failure mode can appear as a short, open, or characteristic degradation. Capacitors have several failure modes, the degree of which depends on the type of capacitor (Table 1).
Polymer Tantalum capacitors manufactured with F-Tech have the lowest failure rate, which is decreasing with time of the accelerated testing (no wear-out) similar to that in Solid Electrolytic Tantalum capacitors. There is no ignition and burning tantalum in failed short SMD-type Solid Electrolytic Tantalum capacitors.
The typical failure mode in Solid Electrolytic and Polymer Tantalum capacitors is low insulation resistance or a short.
No ignition and burning tantalum were found in the Solid Electrolytic Tantalum capacitors that failed short. The black marks on the surface of these capacitors were the areas of the epoxy compound carbonized under the heat propagated from the fault sites in the dielectric at the breakdown event.
In general, the degree of failure is dependent on the degree of protection offered by user circuit design and process controls during both the manufacture of the capacitors and during their attachment to the circuit board. Those failures which have generated a lot of heat are readily observable by the user, the others are not.

To identify capacitors accurately:Examine Physical Appearance: Note the shape, size, color, and terminal configuration of the capacitor.Check Label Information: Look for markings indicating capacitance, voltage rating, tolerance, and manufacturer’s logo.Utilize Testing Equipment: Use a multimeter or capacitor tester to measure capacitance, resistance, and leakage current. [pdf]
Thus, for such concise markings many different types of schemes or solutions are adopted. The value of the capacitor is indicated in “Picofarads”. Some of the marking figures which can be observed are 10n which denotes that the capacitor is of 10nF. In a similar way, 0.51nF is indicated by the marking n51.
The various parameters of the capacitors such as their voltage and tolerance along with their values is represented by different types of markings and codes. Some of these markings and codes include capacitor polarity marking; capacity colour code; and ceramic capacitor code respectively.
Markings of Ceramic Capacitor: The markings on a ceramic capacitor are more concise in nature since it is smaller in size as compared to electrolytic capacitors. Thus, for such concise markings many different types of schemes or solutions are adopted. The value of the capacitor is indicated in “Picofarads”.
How to Read Capacitor Value? A step-by-step guide to interpreting readings Capacitance is measured in farads (F). Common units include microfarads (µF), nanofarads (nF), and picofarads (pF). 1 µF, uF, or mF = 1 microfarad = 10 -6 farads. (Careful — in other contexts, mF is the official abbreviation for millifarads or 10 -3 farads.)
Reading capacitor markings involves identifying several key attributes. The capacitance value often marked directly in microfarads (μF), nanofarads (nF), or picofarads (pF). The voltage rating indicates the maximum voltage the capacitor can handle, marked as a number followed by "V".
The smallest capacitors (made from ceramic, film, or tantalum) use units of picofarads (pF), equal to 10 -12 farads. Larger capacitors (the cylindrical aluminum electrolyte type or the double-layer type) use units of microfarads (uF or µF), equal to 10 -6 farads.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.